Research Article

Characterization of Some Nigerian Coals for Power Generation

Table 3

Comparison of heating values of sample coals estimated from the Boie equation with measured values.

SamplesUltimate analysis, % dry weight Heating value MJ/kg Error%
CarbonHydrogenOxygenNitrogenSulphurMeasured
MJ/kg
Estimated
MJ/kg

Odagbo62.165.879.341.371.0722.6027.00+19.46
Owukpa67.825.889.471.430.6026.5129.78+12.33
Ezimo54.214.429.591.220.5620.9623.26+9.88
Amansiodo66.955.6210.931.580.9227.4829.02+5.60
Inyi49.274.1910.531.240.5619.3922.82+17.68