Research Article

Parametric Investigation of Combustion and Heat Transfer Characteristics of Oscillating Linear Engine Alternator

Figure 8

Top: variation of in-cylinder temperature against time for one steady-state cycle of operation. Bottom: variation of heat flux modeled using Hohenberg correlation. The secondary peak in the temperature curve denotes the gas exchange process from the exhaust.