Summary table of the results deduced from the free tests.

Fire source no.D (mm)tf (min) (g/s) (°C)HRR (W)

Source 11653.170.2155605214.33
Source 21206.970.0985702379.16
Source 39312.000.0565601368.02
Source 47025.270.027540654.27
Source 56037.920.018450436.18
Source 65061.670.011471277.57