Research Article

Liquid Anion Exchange Chromatographic Extraction and Separation of Platinum(IV) with n-Octylaniline as a Metallurgical Reagent: Analysis of Real Samples

Table 7

Determination of platinum(IV) from catalysts.

Sr. no.AlloyPlatinum(IV) taken, μgPlatinum(IV)  *Found by method in μgAverage, % recoveryRSD, %

(1)Pt-Pda-Rha
catalyst on alumina
150149.299.40.6
(2)Pt-Rha
catalyst on alumina
150149.599.60.4
(3)Pt-Pda
catalyst on alumina
150149.899.80.2
(4)Pt
catalyst on alumina
300299.599.80.2

Masked with 20 mg tartrate.
*Average of five determinations.
Composition of synthetic mixtures in percentage
(1) Pt, 0.03–0.25; Rh, 0.005–0.03.
(2) Pt, 0.03–0.15; Pd, 0.02–0.12.
(3) Pt, 0.03–0.20; Pd, 0.03–0.150; Rh, 0.015–0.05.
(4) Pt, 0.3–0.8.