Research Article

A Spectrophotometric Flow Injection Method for Determination of Ultratrace Amounts of Phenylhydrazine by Its Inhibition Effect on the Reaction of Thionin and Nitrite

Table 1

Variable ranges study and optimum conditions for the determination of phenylhydrazine.

Parameter studiedRange studiedOptimum level

Wavelength (nm)200–700602
Sulfuric acid concentration (mol L−1)0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.02.0
Thionin concentration (×10−4 mol L−1)0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.02.5
Sodium nitrite concentration (×10−4 mol L−1)0.1, 0.3, 0.5, 0.7, 0.9, 1.1, 1.3, 1.50.9
Flow rate (mL min−1)0.2, 0.3, 0.4, 0.5, 0.60.3
Mixing coil [I] (cm) [phenylhydrazine + H2SO4 + sodium nitrite]50, 75, 125, 175, 225, 27575
Mixing coil [II] (cm) [phenylhydrazine + H2SO4 + sodium nitrite + thionin]50, 75, 125, 175, 225, 275125
Injection volume (μL)50, 100, 200, 250, 300, 400200