Research Article

Development and Validation of a Reversed-Phase HPLC Method for the Estimation of Zolpidem in Bulk Drug and Tablets

Table 3

Results of the data analysis for the quantitative determination of zolpidem by the proposed method.

Statistical parameterHPLC

Concentration range (μg mL−1)2.5–30
Regression equation
Correlation coefficient ( )0.9996
Standard error on estimation ( )0.049
Standard deviation on slope ( )0.00199
Standard deviation on intercept ( )0.0356
Limit of detection (LOD) (μg mL−1)0.83
Limit of quantification (LOQ) (μg mL−1) 2.5