Research Article
Influence of Heat Treatment on the Corrosion of Microalloyed Steel in Sodium Chloride Solution
Table 4
Potentiodynamic polarization parameters of microalloy steel samples in 3.5% NaCl at room temperature.
| | Tafel data | Linear polarization data | | /mV/decade | /mV/decade | mV | µA | Ω |
| As received | 64.68 | 36.35 | −539 | 2.3645 | 973.9 | First quench | 60.62 | 50.48 | −629 | 4.8089 | 758.6 | Second quench | 85.43 | 54.87 | −664 | 5.0893 | 689.4 | Third quench | 62.64 | 49.37 | −692 | 11.086 | 594.6 |
|
|