Research Article

An Ecofriendly and Stability-Indicating HPLC Method for Determination of Permethrin Isomers: Application to Pharmaceutical Analysis

Table 2

Precision, accuracy, and recovery data for the proposed method.

Isomers Permethrin concentration
(μg/mL)
Precision (RSD, %)Recovery ( )
Intraday ( )Interday
( )
Accuracy ( )
mean (RSD, %)
Target concentration
(μg/mL)
Calculated concentration μg/mL (mean)%±SD

Trans-0.501.852.07100.94 (2.90)7.0 (5.25 as trans)5.2199.240.03
10.000.941.30101.00 (0.43)9.0 (6.75 as trans)6.7199.410.09
20.000.841.78101.28 (0.55)13.0 (9.75 as trans)9.82100.720.14
50.000.731.8099.53 (0.14)

Cis-0.5001.901.94101.42 (2.20)7.0 (1.75 as cis )1.75100.000.03
10.000.701.90101.23 (0.47)9.0 (2.25 as cis )2.26100.440.04
20.001.101.2299.58 (1.98)13.0 (3.25 as cis)3.2499.690.03
50.001.021.9199.96 (0.43)