Research Article
Removal of Pb(II) Ions in Fixed-Bed Column from Electroplating Wastewater of Bursa, an Industrial City in Turkey
Table 2
Column data and parameters obtained for poly(EGDMA-VIM).
| Bed height (cm) | Flow rate (mL/min) | Uptake (mg/g) | (h) | (h) | (h) | (dC/dt)b (mg/L h) |
| 5 | 6 | 44.3 | 2.6 | 18.5 | 15.9 | 0.67 | 8 | 37.8 | 2.3 | 11.8 | 9.5 | 1.12 | 10 | 35.1 | 1.6 | 8.8 | 7.2 | 1.48 |
| 9 | 6 | 65.4 | 11.5 | 48.9 | 37.4 | 0.29 | 8 | 53.7 | 9.2 | 30.1 | 20.9 | 0.51 | 10 | 49.1 | 4.6 | 22.0 | 17.4 | 0.61 |
| 14 | 6 | 90.0 | 26.0 | 105.1 | 79.1 | 0.13 | 8 | 78.3 | 20.2 | 68.3 | 48.1 | 0.22 | 10 | 72.5 | 10.9 | 50.4 | 39.5 | 0.27 |
|
|
aConditions: initial Pb (II) conc. 11.9 mg/L.
bSlope of the breakthrough curve from to .
|