Research Article

Breakthrough Curve Analysis for Column Dynamics Sorption of Mn(II) Ions from Wastewater by Using Mangostana garcinia Peel-Based Granular-Activated Carbon

Table 3

Thomas model parameters for manganese (II) at different conditions using linear regression analysis.

Initial concentration (mg/L)Bed height (cm)Flow rate (mL/min) 𝑘 t h (mL/min-mg) × 10−4 𝑞 0 (mg/g) 𝑅 2

504.515.206085.780.983
704.512.716162.330.975
1004.511.707257.320.931
1003.011.505574.900.890
1004.532.806856.260.956