Research Article

Influence of Ionic Liquid Structure on Supported Ionic Liquid Membranes Effectiveness in Carbon Dioxide/Methane Separation

Table 5

Mechanical stability of supports.

MembraneIonic liquidMaximum pressure difference obtained, kPaAverage pressure difference in 283 K, kPaAverage pressure difference in 288 K, kPaAverage pressure difference in 298 K, kPa

PES[EMIM][Tf2N]4.70n/an/a4.70 ± 0.30
[EMIM][TfO]5.21n/an/a5.10 ± 0.20
PVDF[EMIM][Tf2N]22.8122.14 ± 1.0521.57 ± 1.2420.18 ± 1.53
[EMIM][TfO]21.8221.10 ± 0.6320.60 ± 0.4320.15 ± 0.87
PA[EMIM][Tf2N]22.30n/an/a20.31 ± 1.21
[EMIM][TfO]13.42n/an/a11.20 ± 0.96
[EMIM][Tf2N]55.7551.97 ± 3.4847.68 ± 3.0643.31 ± 4.77
PP[EMIM][TfO]59.5353.68 ± 1.8751.78 ± 3.3949.43 ± 6.23
[BMIM][Tf2N]47.6446.40 ± 1.0245.08 ± 1.7344.59 ± 2.89
[BMIM][TfO]51.7850.65 ± 1.1648.28 ± 1.4847.07 ± 1.00