Research Article
A Validated HPLC-DAD Method for Simultaneous Determination of Etodolac and Pantoprazole in Rat Plasma
Table 2
Data of back-calculated PTZ and ETD concentrations of the calibration standards in rat plasma.
| Drug | Nominal concentration (gmL−1) | Meana ± SD (gmL−1) | Precision (% RSD) | Accuracy (% error) |
| PTZ | 0.1 | 0.11 ± 0.01 | 9.09 | 10 | 0.5 | 0.50 ± 0.01 | 2.78 | 0.67 | 1.0 | 1.09 ± 0.07 | 6.88 | 8.68 | 3.0 | 3.14 ± 0.22 | 7.01 | 4.67 | 5.0 | 4.93 ± 0.39 | 7.91 | −1.43 | 7.0 | 7.44 ± 0.38 | 5.11 | 6.31 | 10.0 | 9.77 ± 0.79 | 8.08 | −2.23 | 15.0 | 14.39 ± 0.68 | 4.72 | −4.07 |
| ETD | 5.0 | 4.97 ± 0.24 | 4.83 | −0.57 | 10.0 | 10.64 ± 0.80 | 7.52 | 6.40 | 15.0 | 14.90 ± 0.52 | 3.49 | −0.67 | 25.0 | 24.13 ± 1.21 | 5.01 | −3.48 | 30.0 | 32.51 ± 1.99 | 6.12 | 8.37 | 35.0 | 36.93 ± 1.39 | 3.76 | 5.51 | 45.0 | 42.25 ± 2.88 | 6.82 | −6.11 | 50.0 | 52.03 ± 1.91 | 3.67 | 4.06 |
|
|
Average of six replicates.
|