Table 3

Intraday and interday accuracy and precision of quality control samples of PTZ and ETD obtained by HPLC-DAD.

Day of analysisPTZETD
Low QCMedium QCHigh QCLow QCMedium QCHigh QC
(0.3 gmL−1)(6 gmL−1)(12 gmL−1)(8 gmL−1)(20 gmL−1)(40 gmL−1)

Day 10.2965.9413.278.3621.2442.63
0.2865.6712.478.1520.3741.65
0.3126.2312.848.9120.5642.19
0.3266.8412.087.6219.6239.41
0.2496.4511.997.9819.1043.54
Day 20.2815.8612.619.1120.2839.16
0.2745.3411.837.6421.7139.08
0.2966.9411.268.1719.3740.42
0.3156.4112.478.7819.8840.37
0.2926.3613.168.9419.7441.28
Day 30.2956.1412.619.6421.1338.68
0.3085.7211.459.8220.0939.46
0.2916.1511.278.4220.5439.44
0.3185.7311.438.6821.8142.18
0.3156.8912.518.2819.3741.72

Mean ± SD (gmL−1)0.29 ± 0.026.18 ± 0.4812.22 ± 0.668.56 ± 0.6520.32 ± 0.8540.75 ± 1.52

Precision (% RSD)6.897.765.407.594.183.73

Accuracy (% error)−3.332.971.837.081.601.87