Research Article

Effect of the Diesel, Inhibitor, and CO2 Additions on the Corrosion Performance of 1018 Carbon Steel in 3% NaCl Solution

Table 5

Equivalent circuit parameters for effect of the addition of CO2 and inhibitor A to base mixture.

Time (min) ()CPEdl
() () * 10−5 () () * 10−3

00.10232.62.420.87
30.0863.6520.8730.98506.41.380.77
60.0854.3216.4950.99621.41.380.75
120.0883.505.9841.00676.31.520.71
180.0865.006.0701.00677.91.440.69
240.0767.589.9881.00621.21.280.71