Research Article

MFI and FAU-Type Zeolites as Trapping Materials for Light Hydrocarbons Emission Control at Low Partial Pressure and High Temperature

Table 2

Composition and sources of hydrocarbon mixtures used for adsorption tests (provided by Praxair).

Mixture HC/N2Composition of individual HC, ppmTotal concentration, C3 ppm

Ethylene/N21280853

Isobutene/N2643857

Toluene/N2358835

C4-C5 alkanesa/N2n-Butane: 123847
Isobutane: 128
n-Pentane: 105
Isopentane: 102
Neopentane: 100
C5: 102

Isobutane-isobuteneb/N2Isobutane: 323858
Isobutene: 320

Equimolar mixture (as C3) of n-butane, isobutane, n-pentane, isopentane, and neopentane.
bEquimolar mixture (as C3) of isobutane and isobutene.