Research Article
Study of Flow-Assisted Corrosion of AZ91D Magnesium Alloy in Loop System Based on Array Electrode Technology
Table 1
The fitting parameters of polarization curves of array electrodes under fluid flow condition with the flow velocity of 5.31 m/s.
| E (electrode) | (mV(SCE)) | (mV/decade) | Corrosion current density (A/cm2) |
| 1 | −1524 | −255.7 | 9.02 × 10−5 | 2 | −1562 | −245.7 | 8.66 × 10−5 | 3 | −1551 | −259.2 | 9.17 × 10−5 | 4 | −1555 | −260.8 | 9.17 × 10−5 | 5 | −1572 | −253.9 | 9.38 × 10−5 | 6 | −1607 | −258.7 | 9.94 × 10−5 | 7 | −1603 | −274.4 | 1.22 × 10−4 | 8 | −1531 | −277.4 | 9.63 × 10−5 | 9 | −1521 | −281.2 | 9.78 × 10−5 | 10 | −1566 | −273.6 | 9.89 × 10−5 | 11 | −1564 | −273.3 | 9.99 × 10−5 | 12 | −1543 | −265.9 | 1.00 × 10−4 | 13 | −1542 | −265.9 | 1.01 × 10−4 | 14 | −1556 | −259.8 | 1.05 × 10−4 | 15 | −1537 | −278.0 | 1.15 × 10−4 |
|
|