Research Article

Layer-by-Layer Assembly of Polysaccharides and 6,10-Ionene for Separation of Nitrogen-Containing Pharmaceuticals and Their Enantiorecognition by Capillary Electrophoresis

Table 3

Comparison stability of the coatings in terms of electroosmotic mobility for the coated capillaries.

SCPC capillary
EO mobility ·104, cm2·V−1·s−1RSD
EO mobility ·104, cm2·V−1·s−1RSD
EO mobility ·104, cm2·V−1·s−1RSD
Variation of EO mobility, RSD
Before treatmentAfter treatment (2 weeks)After treatment (1 month)Over time of life

1.240.081.200.041.150.060.07

DS capillary
EO mobility ·104, cm2·V−1·s−1RSD
EO mobility ·104, cm2·V−1·s−1RSD
EO mobility ·104, cm2·V−1·s−1RSD
Variation of EO mobility, RSD
Before treatmentAfter treatment (1 week)After treatment (5 months)Over time of life

2.000.052.000.031.980.040.01