Summarized averaged values for high concentrations of ammonium nitrogen.

DO = 1 mg/LDO = 2 mg/LDO = 3 mg/LAmmonium set-point = 7.5 mg/L

Oxidized nitrogen, g N/d227255267246
Nitrogen at the reactor outlet, g N/d220191180200
Air consumption, m3/d21273327
Specific air consumption, m3/kg N93106123110