Research Article
Laboratory Research on Fracture-Supported Shielding Temporary Plugging Drill-In Fluid for Fractured and Fracture-Pore Type Reservoirs
Table 5
CDIF-FSDIF flowback performance of the shielding ring.
| Working fluid class | Rock samples | Stratum | Fractures width (μm) | Zd (%) | Before acidification (MPa)/ (%) | After acidification (MPa)/ (%) | Remarks | 0.5 | 1 | 1.5 | 0.1 | 0.5 | 1 |
| FSDIF | 1# | P2ch | 61.1 | 100.00 | 87.72 | 89.34 | — | 98.35 | 110.28 | — | Fracture | 2# | P2ch | 20.3 | 99.86 | 88.07 | 90.56 | — | 88.72 | 120.83 | — | Fracture | 3# | T1f | — | 99.71 | 71.23 | 91.35 | — | 73.86 | 105.37 | — | Block |