Research Article

Microchannels Effective Method for the Extraction of Oleuropein Compared with Conventional Methods

Table 5

ANOVA for response surface reduced quadratic model for MC method.

SourceSum of squaresdfMean square values values

Model2339.9514167.1448.72<0.0001 significant
A-flow rate383.881383.88111.89<0.0001 significant
B-residence time3.4813.481.020.3297 not significant
C-PH60.70160.7017.690.0008 significant
D-temperature10.9926 not significant
AB25.31125.317.380.0159 significant
AC20.58120.586.000.0271 significant
AD81.31181.3123.700.0002 significant
BC21.05121.056.140.0256 significant
BD73.36173.3621.380.0003 significant
CD66.66166.6619.430.0005 significant
256.851256.8574.86<0.0001 significant
0.03410.0340.9225 not significant
61.70161.7017.980.0007 significant
8.3318.332.430.1399 not significant
Residual51.46153.43
Lack of fit39.5394.392.210.1735 not significant
Pure error11.9361.99
Cor total2391.4129

Std. Dev = 1.85

:  -squared, : adjusted -squared, and :  -squared.