ElectrodeMethodLinear range (ppb)LOD (ppb)References

MgO–Nafion/GCEDP-ASV, ABS pH = 5.0Cd(II): 1.1–23.6
Pb(II): 2.1–414
[22]
BiNPs/GCEDP-ASV, ABS pH = 4.55.0–60.0Cd(II): 0.4; Pb(II): 0.8[25]
AuNPs/GCEDP-ASV, ABS pH = 5.0Cd(II): 20.7; Pb(II): 11.2[26]
Padpa/Ru/GCEDP-ASV, HCl 0,1 MCd(II): 21.7; Pb(II): 9.8[27]
Diatomite-MPTMS/GCEDP-ASV; ABS; pH = 4.5Cd(II): 20–300
Pb(II): 20–150
Cd(II): 15.9; Pb(II): 6.9This work

Glassy carbon electrode (GCE); bismuth nanoparticles (BiNPs); gold nanoparticles (AuNPs); tris(2,2′-bipyridyl)Ru(II) (Padpa/Ru).