Experimental design matrix and results for process optimization.

Run-removal-removal
PMS/gIL/gT/°CTime/minExperimental results/%Predicted values/%

112501554.355.1
222501565.967.3
314501568.668.0
424501572.772.7
51.5340575.676.2
61.5360555.555.5
71.53402590.791.5
81.53602570.971.1
91350557.257.6
102350562.164.6
1113502572.771.6
1223502580.481.5
131.52401576.677.6
141.54401584.684.0
151.52601552.354.3
161.54601565.766.2
1713401574.174.6
1823401575.273.0
1913601543.944.0
2023601565.362.6
211.5250569.165.9
221.5450570.570.3
231.52502578.576.6
241.54502589.490.4
251.53501591.991.9
261.53501593.791.9
271.53501592.491.9
281.53501591.291.9
291.53501590.791.9