Research Article

The Oxygen Generation Performance of Hollow-Structured Oxygen Candle for Refuge Space

Table 1

Oxygen concentration, oxygen generation, and the average OGR.

Radius of the hollow structure (mm)The initial oxygen concentration (%)The oxygen concentration at the end of reaction (%)The reaction time (min)The actual volume (L)The theory volume (L)The ratio of actual volume to theoretical volume (%)The average OGR (L·min−1)

020.728.8634.4349.6169.45.74
520.6231.435.745.9449.6192.68.06
920.5832.055.348.7549.6198.39.2
1220.632.1548.4549.6197.79.69
15.520.62324.348.3649.6197.511.25