Research Article

Electrochemical Removal of Humic Acids from Water Using Aluminum Anode: Influence of Chloride Ion and Current Parameters

Table 2

Experimental parameters and corresponding energy consumption for 90% HA removal: starting concentration = 50 mg·L−1, volume = 0.5 L.

Number of the experimentElectrolyteCurrent density (A·m−2)Current intensity (A)Voltage (V)Time (min)Energy (joule)

1NaCl 0.001 M100.0756.130824
2NaCl 0.08 M100.0751.21581
3NaCl 1.5 M100.0750.81036
4NaCl 0.001 M500.37525.1158470
5NaCl 0.04 M500.3752.8503150
6NaCl 0.08 M500.3752.220990
7NaCl 1.5 M500.3751.010225
8NaCl 0.001 M1000.753.0151890
9NaCl 0.08 M1000.752.210924
10NaCl 1.5 M1000.751.110462
11NaNO3 0.08 M100.0753.5901418
12NaNO3 0.08 M500.3754.31009675
13NaNO3 0.08 M1000.755.3102226