Research Article

Analysis of CaF2 Precipitation Process in the Selected Static Mixers

Table 1

Dimensions of the tested devices.

KofloKenicsPipe

Number of mixing elements66
Inner diameter (m)0.0150.01360.015
Device length (m)0.1860.1650.186
Thickness of mixing elements (m)0.00170.004
Length/diameter12.4012.1312.40
18.6718.67
31.0731.07
Device active volume for
Lm/d = 12.416.414.532.8
Lm/d = 18.6724.749.5
Lm/d = 31.07 (mL = 10−6 m3)41.082.3