Research Article

Kinetic Analysis of Low-Rank Coal Pyrolysis by Model-Free and Model-Fitting Methods

Table 4

Calculation results of coal WJG.

Method (°C/min)E (kJ/mol)A (1/S)R2

The general integral5217.049.55 × 10120.9940
10207.721.78 × 10120.9960
15187.766.92 × 10100.9919
20187.236.03 × 10100.9874
MacCallum–Tanner5221.862.57 × 10130.9947
10212.714.79 × 10120.9965
15192.741.78 × 10110.9930
20192.351.62 × 10110.9891
Average200.348.51 × 10110.9928
Kissinger203.055.99 × 10110.9700
FWO192.830.9920