Research Article
Kinetic Analysis of Low-Rank Coal Pyrolysis by Model-Free and Model-Fitting Methods
Table 6
Calculation results of coal HCG.
| Method | (°C/min) | E (kJ/mol) | A (1/S) | R2 |
| The general integral | 5 | 276.67 | 3.98 × 1017 | 0.9995 | 10 | 252.23 | 5.13 × 1015 | 0.9997 | 15 | 211.63 | 8.71 × 1012 | 0.9991 | 20 | 210.43 | 6.76 × 1012 | 0.9998 | MacCallum–Tanner | 5 | 282.17 | 1.41 × 1018 | 0.9996 | 10 | 257.84 | 1.70 × 1016 | 0.9997 | 15 | 216.94 | 2.51 × 1013 | 0.9992 | 20 | 215.86 | 1.95 × 1013 | 0.9998 | Average | 240.47 | 1.05 × 1015 | 0.9995 | Kissinger | — | 223.67 | 1.53 × 1013 | 0.9976 | FWO | — | 264.33 | — | 0.9900 |
|
|