Research Article

Characteristics of Corrosion Related to Ash Deposition on Boiler Heating Surface during Cofiring of Coal and Biomass

Table 4

Fitting correlations of corrosion mass gain of different metal samples coated with different fuel ash.

FuelsFitting correlations (ΔG = 1/2 + C)kR2

No fuel ashΔG = 0.1695τ1/2 − 0.198020.16950.98618
50%B1 + 50%C1ΔG = 0.39923τ1/2 − 0.365980.39920.99751
50%B1 + 50%C2ΔG = 0.37439τ1/2 − 0.381880.37440.99388
50%B2 + 50%C1ΔG = 0.29955τ1/2 − 0.248790.29960.99752
50%B2 + 50%C2ΔG = 0.23953τ1/2 − 0.110910.23950.96897
50%B3 + 50%C1ΔG = 0.19297τ1/2 − 0.086060.19300.97963
50%B3 + 50%C2ΔG = 0.18106τ1/2 − 0.097930.18110.97704