Research Article
Characteristics of Corrosion Related to Ash Deposition on Boiler Heating Surface during Cofiring of Coal and Biomass
Table 4
Fitting correlations of corrosion mass gain of different metal samples coated with different fuel ash.
| Fuels | Fitting correlations (ΔG = kτ1/2 + C) | k | R2 |
| No fuel ash | ΔG = 0.1695τ1/2 − 0.19802 | 0.1695 | 0.98618 | 50%B1 + 50%C1 | ΔG = 0.39923τ1/2 − 0.36598 | 0.3992 | 0.99751 | 50%B1 + 50%C2 | ΔG = 0.37439τ1/2 − 0.38188 | 0.3744 | 0.99388 | 50%B2 + 50%C1 | ΔG = 0.29955τ1/2 − 0.24879 | 0.2996 | 0.99752 | 50%B2 + 50%C2 | ΔG = 0.23953τ1/2 − 0.11091 | 0.2395 | 0.96897 | 50%B3 + 50%C1 | ΔG = 0.19297τ1/2 − 0.08606 | 0.1930 | 0.97963 | 50%B3 + 50%C2 | ΔG = 0.18106τ1/2 − 0.09793 | 0.1811 | 0.97704 |
|
|