Research Article
Assessment of Sewage Water Treatment Using Grinded Bauxite Rock as a Robust and Low-Cost Adsorption
Table 3
Complete analysis of the raw waste water and different treated effluents.
| Parameter | Raw | Blank | % R | 1 g/l | %R 1 g/l | 2 g/l | %R 2 g/l | 3 g/l | %R 3 g/l | 4 g/l | %R 4 g/l | 5 g/l | %R 5 g/l |
| pH | 7.5 | 7.9 | | 8.0 | | 8.0 | | 7.8 | | 7.7 | | 7.5 | | EC (μS) | 576 | 587 | | 595 | | 600 | | 604 | | 607 | | 614 | | TDS (mg/l) | 371 | 378 | | 383 | | 386 | | 389 | | 391 | | 395 | | Turbidity (NTU) | 111 | 87 | 22 | 68 | 21 | 62 | 28 | 59 | 32 | 57 | 34 | 53 | 39 | COD | 326 | 256 | 22 | 134 | 48 | 98 | 61 | 83 | 67 | 70 | 72 | 65 | 75 | BOD | 243 | 196 | 20 | 104 | 47 | 71 | 63 | 60 | 69 | 51 | 74 | 47 | 76 | BOD/COD | 0.75 | 0.74 | | 0.72 | 0.73 | | | 0.72 | | 0.72 | | 0.72 | | TSS | 124 | 70 | 43 | 51 | 28 | 47 | 33 | 45 | 36 | 45 | 36 | 44 | 38 | FC | 5.5 × 107 | 4.9 × 106 | 90.26 | 4.2 × 105 | 91.30 | 3.4 × 105 | 93.00 | 2.8 × 105 | 94.33 | 2.4 × 105 | 94.99 | 2.0 × 105 | 95.99 |
|
|