Review Article
Textile Industry Effluent Treatment Techniques
Table 3
Cost of technologies and treatments of wastewater effluent in textile.
| Technology for treatment of textile effluent | Treatment cost (US$/m3) | Reference |
| Chemical and ion exchange process | 3.5 US$/m3 | [102] | Biologically pretreated textile wastewater followed by chemical treatment methods (Fe3/H2O2) | 0.57 US$/m3 | [103] | Electro-Fenton | 3.13 US$/m3 | [104] | Integrated | EC + F (1.65 US$/m3) | [105] | Electrocoagulation, H2O2/Fe2+/UV with adsorption | EC + PF (2.3 US$/m3) | | Electrocoagulation | Fe electrode (1.562 US$/m3) | [106] | Al electrode (1.851 US$/m3) | Hybrid photo-Fenton and membrane (MF-NF-AOP and MF-AOP-NF) | MF-NF-AOP (0.421 US$/m3), MF-AOP-NF (0.736 US$/m3) | [107] | Photocatalytic processes under UV and visible light sources | H2O2/UV-Vis/Fe2+ (100 mg·L−1 H2O2/4 mg·L−1 Fe2+) (0.91 US$/m3) | [108] | H2O2/UV-Vis/Fe3+ (100 mg·L−1 H2O2/20 mg L−1 Fe3+/80 mg·L−1 H2C2O4) (1.07 US$/m3) | H2O2/UV (100 mg·L−1 H2O2) (2.24 US$/m3) |
|
|