Survey of Green Radio Communications Networks: Techniques and Recent Advances
Table 1
Classification of some energy efficiency metrics.
Level
Units
Description
Facility level
Power usage efficiency is a ratio 1.
Defined as the ratio of total facility power consumption to total equipment power consumption
Data centre efficiency is a percentage (%)
Defined as the reciprocal of PUE
Equipment level
PA efficiency is a ratio
The ratio of output to input power
W/Gbps
The ratio of energy consumption to effective system capacity
Gbps/W
The ratio of useful work to power consumption
MIPS/W
Millions of instructions per second per Watt
MFLOPS/W
Millions of floating-point operations per second per watt
Access node level
b/s/Hz
Spectral efficiency refers to the rate at which information can be transmitted over a given bandwidth in a specific communication system
b/s/Hz/W
The spectral efficiency per Watt
(b·m)/s/Hz/W
The radio efficiency measures the rate at which data are transmitted and the transmission distance attainable for a given bandwidth and power resources supplied
J/bit
The energy consumption rating is defined as the number of bits transmitted per Joule of energy
Network level
km2/W
The ratio of coverage area to site power consumption
W/km2
The power consumed per unit area
Users/W
The ratio of users served during the peak traffic hour to site power consumption
J/bit/m2
The energy consumption with respect to the number of transferred bits and the coverage area
W/bps/m2
The average power usage with respect to the average transmission rate and the coverage area