Master RS1 S2S3S10 S11 S12 S19 S20 S21
(Phase R)(Phase S)(Phase T)(Phase R)(Phase S)(Phase T)(Phase R)(Phase S)(Phase T)

Vpp = 8.56 V 8.516.526.488.316.125.957.855.455.23
Vpp = 7.53 V7.495.545.477.275.155.026.794.354.29
Vpp = 5.82 V5.633.283.415.463.153.084.982.782.63

(b)

Master RS31 S32 S33 S46 S47 S48
(Phase R)(Phase S)(Phase T)(Phase R)(Phase S)(Phase T)

Vpp = 8.56 V7.224.824.676.874.384.25
Vpp = 7.53 V6.133.583.275.782.972.91
Vpp = 5.82 V4.431.981.834.231.251.18