Research Article
Tooth Fracture Detection in Spiral Bevel Gears System by Harmonic Response Based on Finite Element Method
Table 1
System parameters.
| | Active gear | Driven gear |
| Modulus | 6 | Pressure angle (°) | 20 | Tooth number | 15 | 46 | Tooth width (m) | 0.44 | 0.44 | Shaft angle (°) | 90 | Mean spiral angle (°) | 35 |
|
|