Research Article

Rotor Speed Control of a Direct-Driven Permanent Magnet Synchronous Generator-Based Wind Turbine Using Phase-Lag Compensators to Optimize Wind Power Extraction

Table 2

PMSG parameters.

ParametersValue

Generator typePMSG
Rated mechanical power, P (MW)2
Rated apparent power, S (MVA)2.24
Rated L-L voltage, (V)690 (rms)
Rated power factor, pf0.89
Rated rotor speed, (rpm)22.5
Pole pairs, 26
Rated mechanical torque (kNm)848.83
Flux linkage, (Wb)4.971
Stator winding resistance, (mΩ)0.821
Stator -axis inductance, (mH)1.573
Stator -axis inductance, (mH)1.573