Research Article
Investigation and Control of VIVs with Multi-Lock-in Regions on Wide Flat Box Girders
Table 1
Design parameters of wind tunnel tests.
| Parameters | Symbol | Actual values | Required values | Testing values |
| Height (m) | | 3.5 | 0.0583 | 0.058 | Width (m) | | 42.0 | 0.7 | 0.700 | Length (m) | | 880 | __ | 2.095 | Mass/unit length (kg·m−1) | | 27600 | 7.667 | 7.667 | Mass moment of inertia/unit length (kg·m2)·m−1 | | 5137700 | 0.3987 | 0.399 | First vertical natural frequency (Hz) | | 0.1745 | 2.218 | 2.274 | Vertical damping ratio (%) | | 0.5 | 0.389 | 0.442 | First torsional natural frequency (Hz) | | 0.3973 | 5.417 | 5.404 | Torsional damping ratio (%) | | 0.5 | 0.439 | 0.422 | Turbulent intensity (%) | | | | <0.5% |
|
|