Details of one stator current phase for both healthy and faulty open-circuit at cases.

Max detailsmaxmaxmaxmaxmaxmax

Input
 Healthy state2.5683.1261.92810.677.0141.228
 Open-circuit state 2.2612.4123.2067.6326.5020.909