Research Article

Fault-Tolerant Control Strategy for Neutral-Point-Clamped Three-Level Inverter

Table 3

The sequence and action time of voltage vectors in each region.

RegionSwitching sequenceAction time

I-1POO-PPO-PPP-PPP-PPO-POO
I-2POO-PPO-PPP-PPP-PPO-POO
I-3PON-POO-PPO-PPO-POO-PON
I-4PON-POO-PPO-PPO-POO-PON
I-5PNN-PON-POO-POO-PON-PNN
I-6PON-PPN-PPO-PPO-PPN-PON
IV-1NNN-NNO-NOO-NOO-NN0-NNN
IV-2NNN-NNO-NOO-NOO-NN0-NNN
IV-3NNO-NOO-NOP-NOP-NOO-NNO
IV-4NNO-NOO-NOP-NOP-NOO-NNO
IV-5NOO-NOP-NPP-NPP-NOP-NOO
IV-6NNO-NNP-NOP-NOP-NNP-NNO