Research Article
Model Predictive Voltage Control with Optimal Duty Cycle for Three-Phase Grid-Connected Inverter
Table 2
Comparison of THD for MPVC and MPCC methods.
| | THD (%) | Conventional MPVC | Proposed MPVC | Conventional MPCC | Proposed MPCC |
| Sampling Time (μs) | Grid Current | Capacitor filter Voltage | Grid Current | Capacitor filter Voltage | Grid Current | Grid Current |
| 25 | 0.98 | 3.52 | 0.7 | 2.8 | 3.2 | 1.94 |
| 50 | 2.95 | 6.03 | 1.91 | 4.05 | 4.29 | 2.54 |
|
|