Research Article

A Simplified Finite Control Set Model Predictive Control for T-Type Three-Level Power Conversion System Based on LCL Filter

Figure 15

Experimental results of the PCS prototype. (a) Grid voltage and current waveforms in battery-discharging condition (unity PF). (b) Grid voltage and current waveforms in battery-charging condition (unity PF). (c) Grid voltage and current waveforms in battery-discharging condition (|PF| = 0.9). (d) Grid voltage and current waveforms in battery-charging condition (|PF| = 0.9). (e) Output line voltage waveforms of T-type 3L PCS.
(a)
(b)
(c)
(d)
(e)