Research Article

A Simplified Finite Control Set Model Predictive Control for T-Type Three-Level Power Conversion System Based on LCL Filter

Table 1

Selection guide for candidate vectors based on a, b, c, and N.

[a, b, c, N]Candidate vector

1001P0N P00 0NN PP0 00N
1002PNN PN0 P00 0NN
1003PNN P0N P00 0NN
1004P00 0NN P0P 0N0 (PPP 000 NNN)
1005P00 0NN PP0 0NN (PPP 000 NNN)
1006PN0 P00 0NN P0P 0N0
1101PPN 0PN PP0 00N
1102P0N P00 0NN PP0 00N
1103P0N PPN PP0 00N
1104PP0 00N 0P0 N0N (PPP 000 NNN)
1105PP0 00N 0PN 0P0 N0N
1106P00 0NN PP0 00N (PPP 000 NNN)
01010PN NPN 0P0 N0N
0102PP0 00N 0P0 N0N (PPP 000 NNN)
01030PN PP0 00N 0P0 N0N
0104NP0 0P0 N0N 0PP N00
0105NPN NP0 0P0 N0N
01060P0 N0N 0PP N00 (PPP 000 NNN)
0111NP0 0P0 N0N 0PP N00
01120PP N00 00P NN0 (PPP 000 NNN)
01130P0 N0N 0PP N00 (PPP 000 NNN)
0114NPP N0P 0PP N00
0115NP0 NPP 0PP N00
0116N0P 0PP N00 00P NN0
00110PP N00 00P NN0 (PPP 000 NNN)
00120NP 00P NN0 P0P 0N0
001300P NN0 P0P 0N0 (PPP 000 NNN)
0014N0P NNP 00P NN0
0015N0P 0PP N00 00P NN0
0016NNP 0NP 00P NN0
1011P00 0NN P0P 0N0 (PPP 000 NNN)
1012PNP PN0 P0P 0N0
1013PN0 P00 0NN P0P 0N0
10140NP 00P NN0 P0P 0N0
101500P NN0 P0P 0N0 (PPP 000 NNN)
10160NP PNP P0P 0N0