Research Article

Optimal Hemoglobin A1c Levels for Screening of Diabetes and Prediabetes in the Japanese Population

Table 3

Sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios, and accuracy for detecting diabetes defined by OGTT.

HbA1c (%)Youden indexSensitivity (%)Specificity (%)Positive predictive value (%)Negative predictive value (%)Positive likelihood ratioNegative likelihood ratioAccuracy

≧5.60.535 94.2 45.7 10.4 99.2 1.70.148.8
≧5.70.625 94.2 59.3 13.3 99.3 2.30.161.5
≧5.80.685 91.9 70.6 17.3 99.2 3.10.171.9
≧5.90.714 88.4 80.2 23.0 99.0 4.50.180.7
6.00.725 83.7 87.6 31.2 98.8 6.80.287.4
≧6.10.660 79.1 93.5 38.2 98.5 12.10.292.6
≧6.20.627 69.8 96.3 55.6 97.9 18.70.394.6
≧6.30.557 65.1 97.6 64.4 97.7 27.00.495.6
≧6.40.526 57.0 98.7 74.2 97.2 43.10.496.1
≧6.50.449 53.5 99.1 79.3 97.0 57.30.596.2