Treatment Efficiency by means of a Nonthermal Plasma Combined with Heterogeneous Catalysis of Odoriferous Volatile Organic Compounds Emissions from the Thermal Drying of Landfill Leachates

Table 2

Odour concentration, VOCOD, NH3, H2S, and TOC concentrations, and % reduction in each day.

ParameterDay 1Day 2Day 3Average (Days 1–3)Day 4.1Day 4.2Day 4.3Day 4.4

Odour conc. (dynamic olfactom.)
 Inlet conc. (ouE/m3)13,77738,96820,63224,459
 Outlet conc. (ouE/m3)5,1612,5804,8124,184
 Reduction (%)63937778
 Inlet conc. (μg/m3)148.4470.6195.9271.698.392.641.242.5
 Outlet conc. (μg/m3)51.8145.855.284.345.819.3
 Average VOCOD concentration reduction (%)656972695353
NH3
 Inlet conc. (ppmV)139.3143115132.4265.2265.2170.5170.5
 Outlet conc. (ppmV)18.119.21316.850.540.660.243.7
 Reduction (%)8787898781856574
H2S
 Inlet conc. (ppmV)3.74.02.03.2<0.5<0.5<0.5<0.5
 Outlet conc. (ppmV)<0.5<0.5<0.5<0.5<0.5<0.5<0.5<0.5
 Reduction (%)>86>88>75>83n.a.*n.a.*n.a.*n.a.*
TOC
 Inlet conc. (mgC/m3)62.346.551.553.4167.3150.1140140
 Outlet conc. (mgC/m3)10.55.73.56.672.3129.3102.5120.8
 Reduction (%)8388938857142714

Plasma frequency (Hz)200200200200150200100

Effluent : dilution air ratio (v : v)1 : 53 : 5

Catalyst (temperature)MnO2 (150°C)MnO2 (50°C)

n.a.: not applicable; the compound was not detected at the inlet or at the outlet.
Note: the results indicated as < (value) correspond to the LOD of the corresponding technique.