Research Article
Performance Evaluation of Antlion Optimizer Based Regulator in Automatic Generation Control of Interconnected Power System
Table 4
Standard deviation of optimized parameters of the regulator.
| Parameters | ALO | GSA [17] | PSO [18] | GA [19] | | | | | | | | |
| | 0.02923 | 0.03773 | 0.02425 | 0.07720 | 0.02604 | 0.08461 | 0.09729 | 0.20687 | | 0.04107 | 0.03315 | 0.04475 | 0.09833 | 0.08416 | 0.04759 | 0.18872 | 0.21313 | | 0.00582 | 0.00102 | 0.00045 | 0.00168 | 0.00153 | 0.01403 | 0.00892 | 0.00717 | | 0.01763 | 0.04563 | 0.10256 | 0.00769 | 0.09639 | 0.08158 | 0.05800 | 0.15550 | | 0.08957 | 0.08807 | 0.04916 | 0.11771 | 0.16726 | 0.08363 | 0.17955 | 0.07945 | | 0.00343 | 0.00174 | 0.00173 | 0.00385 | 0.00280 | 0.01080 | 0.00310 | 0.0105937 | ā | 0.00184 | 7.16E ā 06 | 0.0212 | 0.000419 | 0.38 | 0.011 | 1.76 | 0.013 |
|
|