Research Article

The Hysteresis Performance and Restoring Force Model for Corroded Reinforced Concrete Frame Columns

Table 4

Computed results of ultimate load and peak displacement and those acquired by FE simulation and experiments.

Corrosion rate (%)Formula Numerical ABAQUS Experiment [13] Relative error (%)

Ultimate load (kN)
052.252.350.154.1%
549.047.949.65−1.3%
1046.544.849.5−6.1%
1544.539.343.542.2%

Peak displacement (mm)
023.624.522.544.7
522.918.322.372.4
1020.825.919.755.3
1517.922.414.3225.0