Research Article
A Novel Electric Bicycle Battery Monitoring System Based on Android Client
Table 1
Comparison of acquisition value with measured value.
| Parameters/unit | Acquired data | Measured data | Error (%) |
| Voltage of cell 1/V | 3.9852 | 3.9860 | −0.020 | Voltage of cell 2/V | 3.9832 | 3.9831 | 0.003 | Voltage of cell 3/V | 3.9574 | 3.9579 | −0.013 | Voltage of cell 4/V | 3.9637 | 3.9630 | 0.018 | Voltage of cell 5/V | 3.9845 | 3.9850 | −0.013 | Voltage of cell 6/V | 3.9802 | 3.9807 | −0.013 | Voltage of cell 7/V | 3.9795 | 3.9788 | 0.018 | Voltage of cell 8/V | 3.9832 | 3.9839 | −0.018 | Voltage of cell 9/V | 3.9808 | 3.9817 | −0.023 | Voltage of cell 10/V | 3.9809 | 3.9815 | −0.015 | Voltage of cell 11/V | 3.9810 | 3.9816 | −0.015 | Voltage of cell 12/V | 3.9797 | 3.9789 | 0.020 | Voltage of cell 13/V | 3.9763 | 3.9770 | −0.018 | Current/A | 1.621 | 1.62242 | −0.088 | Current/A | −12.136 | −12.11489 | −0.174 | Temperature 1/°C | 19.9 | 19.8 | 0.505 | Temperature 2/°C | 19.9 | 19.9 | 0.000 | Temperature 3/°C | 19.8 | 19.9 | −0.503 | Temperature 4/°C | 19.4 | 19.7 | −1.523 | Temperature 5/°C | 19.7 | 19.6 | 0.510 |
|
|