Research Article

Study and Development of a Complete System for Recovery, Recycle, and Disposal of Refrigerant Gas from Existent Plants

Table 3

(a) R410 analysis before recovery operation. (b) R410 analysis after recovery operation.
(a)

Oil, %Humidity, ppmAcidity, ppmTitle, %R32, %R125, %Noncond., %

3157n.m.99.9948.0751.920.45
3.1299n.m.99.9948.5351.460.20
2.213815599.9949.6350.360.27
1.73116699.9950.2549.741.14
2.5115n.m.99.9949.9150.080.27
2.7197n.m.99.9949.9650.030.24
4.111519999.9950.5349.460.17
1.795n.m.99.9949.8350.161.21
3.2223n.m.99.9948.2351.762.03
3.51679699.9950.2949.700.32
2.2144n.m.99.9949.0750.920.55

(b)

Oil, %Humidity, ppmAcidity, ppmTitle, %R32, %R125, %Noncond., %

0.5155n.m.99.9949.8450.150.40
n.m.285n.m.99.9949.3450.650.21
0.313015099.9950.6149.380.26
n.m.3016099.9949.9650.030.43
n.m.101n.m.99.9950.1949.800.21
n.m.201n.m.99.9949.8750.12n.m.
0.911719199.9949.9350.060.19
n.m.96n.m.99.9949.0050.990.94
n.m.202n.m.99.9948.7751.220.38
0.21608299.9950.4949.500.23
n.m.102n.m.99.9949.9450.050.22