Research Article

Study and Development of a Complete System for Recovery, Recycle, and Disposal of Refrigerant Gas from Existent Plants

Table 4

Technical data of the adsorbent columns CD1 and CD2 of Figure 2.

Design parameters

Gas velocity<0.3 m/min
Liquid velocity0.25 m/min
Minimum bed length1.2 m/min
Molecular sieveCRYOSIV, Grace MS594
Sieve capacity10%
Sieve density790 kg/m3

Input

Total mass flow rate600 kg/hr
Liquid density at 398 K800 kg/m3
Max. inlet Humidity1000 ppm
Max. outlet Humidity5 ppm
Gas amount for column1000 kg

Output

Total volumetric flow rate0.375 m3/hr
Water amount to be removed0.995 kg
Water flow rate to be removed0.299 kg/hr
Molecular sieve amount9.95 kg
Sieve volume0.013 m3
Calculated column inner diameter0.219 m
Commercial column inner diameter0.220 m
Bed length1.2 m
Column inner volume0.046 m3
Sieve weight36.02 kg