Research Article
Analysis of Wellhead Uplift in Offshore Thermal Recovery by Using Finite Element Numerical Simulation
Table 4
Radial temperature distribution to the completion string.
| Depth/m | Fluid temperature/°C | ø244.475 mm (9 5/8′′) casing temperature/°C | Cement boundary temperature/°C | ø399.725 mm (13 3/8′′) casing temperature/°C | Cement sheath boundary temperature/°C | ø508 mm (20′′) pipe temperature/°C |
| 0 | 270 | 119.56 | 82.43 | 82.43 | 34.57 | 34.57 | 10 | 269.84 | 119.5 | 82.39 | 82.39 | 34.56 | 34.56 | 20 | 269.68 | 119.43 | 82.35 | 82.35 | 34.55 | 34.55 | 30 | 269.51 | 119.36 | 82.3 | 82.3 | 34.54 | 34.54 | 40 | 269.34 | 106.13 | 66.39 | 66.39 | 15.18 | 15.18 | 50 | 269.17 | 106.06 | 66.36 | 66.36 | 15.18 | 15.18 | 60 | 269.02 | 141.45 | 109.32 | 109.32 | 67.91 | 67.91 | 70 | 268.87 | 141.53 | 109.46 | 109.46 | 68.12 | 68.12 | 80 | 268.72 | 141.62 | 109.6 | 109.6 | 68.33 | 68.33 | 90 | 268.58 | 141.7 | 109.74 | 109.74 | 68.54 | 68.54 | 100 | 268.43 | 141.79 | 109.88 | 109.88 | | | 190 | 267.12 | 142.54 | 111.14 | 111.14 | | | 280 | 265.82 | 143.29 | 112.39 | 112.39 | | | 360 | 264.66 | 143.96 | 113.51 | 113.51 | | |
|
|