Research Article
Design Tools for Bolted End-Plate Beam-to-Column Joints
Figure 6
versus (a) and versus (b) curves for beam-to-column assemblages combining I section beams (varying from IPE 200 to IPE 750) and wide flange section columns (varying from HEM 120 to HEM 400) obtained using design charts.