Research Article

Method for Evaluating the Effect of the Design and the Environmental Conditions of the Manufacturing Cells toImprove Work Performance

Table 2

Evaluation of compliance with official standards.

Ergonomic factorOfficial standardResults of measurementComplies

Lighting levelsNOM-025-STPS-2008, lighting conditions in workplace, determine the minimum lighting levels that must affect the work plane, for each type of visual task or work area [19].Minimum lighting levels: interior—50 lux; simple visual requirement: 200 lux; moderate detail distinction: 300 luxInterior: 104 lux; simple visual requirement: 220 lux; moderate detail distinction; 308 lux

Noise levelsNOM-011-STPS-2001, safety and hygiene conditions in workplace where noise is generated determine the maximum permissible limits of exposure of workers to stable, unstable, or impulsive noise during the exercise of their duties [20].During a maximum permissible exposure time of 8 hours, a noise exposure level of 90 dB is allowed.Minimum: 77 dB
Maximum: 88.8 dB

Thermal environmentNOM-001-STPS-2008, artificial ventilation for worker comfort or due to the requirements of activities in the workplace [21].
NOM-015-STPS-2001, maximum permissible limits of exposure to high thermal conditions [22].
Relative humidity between 20% and 60%. Air temperature of 22°C ± 2°C for times of cold environment and 24.5°C ± 1.5°C for hot times.
Maximum allowable temperature in a light duty regime 30°C.
Humidity: 30% to 41%
Temperature: 26°C to 28°C